FUJITSU P42HNA10 - P42HHS10W/E - ERROR TYPES - CHECKS - TROUBLESHOOTING FLOW CHARTS & Universal Remote Control Codes

$
0
0
ERROR DISPLAYS
Three kinds of error messages are displayed on the screen, and the power is turned off 10 sec later.
LED error is displayed continuously after the power is turned off.
ERROR TYPES AND CHECK POINTS
OSD
On screen display
Cause
Check point

ERROR MESSAGE CONDITION 1
Fan protector operated
# Fan (Display unit)
# Main power PCB (Display unit)
# Main PCB (Display unit)

ERROR MESSAGE CONDITION 2
Temperature protector operated.
# Ambient temperature of unit
# Main PCB (Display unit)
# Temp. sensor IC757 (Display unit)

ERROR MESSAGE CONDITION 3
EEPROM error
# Main PCB (Display unit)
# Main(Digital/Video) PCB
(Selector unit)
LED DISPLAY
LED lamp display status
Cause
Check point

Steady light (Red)
Stand-by status
   =====
Continuous.  Flashes continuously (Red)
# No power
# Power supply protector
operated

# Main power PCB
# PDP panel
1 time.  Flashes once every 4 sec. (Red)
Fan protector operated
# Fan
# Main power PCB
# Main PCB

2 times.  Flashes twice every 5 sec. (Red)
# Temperature protector
operated
# PDP panel AC error
# Ambient temperature of unit
# Temperature sensor IC757
# Main PCB
# Pane AC.

3 times.  Flashes three times every 6 sec. (Red)

EEPROM error
Main PCB
5 times.  Flashes five times every 8 sec. (Red)
Audio circuit faulty
Audio PCB Assy
SELECTOR UNIT
LED lamp display status
Cause
Check point

Steady light (Red)
Stand-by status


Continuous.  Flashes continuously (Red)
* No power
* Power supply protector
operated

Main power PCB
3 times.  Flashes three times every 6 sec. (Red)

EEPROM error
Main(Digital/Video) PCB
4 times.  Flashes four times every 7 sec. (Red)

Main(Digital) circuit faulty
Main(Digital) PCB
5 times.  Flashes five times every 8 sec. (Red)
Audio circuit faulty
Audio PCB Assy
TROUBLESHOOTING FLOW CHARTS
Lamp Blinking [Since a voltage is applied to the Main Power PCB heat sinks while the set is operating, do not touch the heat sinks.]
CLICK ON CHARTS TO MAGNIFY
POWER SUPPLY PROTECTOR OPERATED
UNIVERSAL REMOTE CONTROL CODES
GE Universal remote : 0197 0051
RCA RCR 311W : 1228, 1027, 1186, 1229, 1045
RCA RCR 312W: 10809, 10683, 10853
RCA RCU 300 TMS: 010
URC 3050: 1223
URC 2054: 10809,10179,  10186,10683,10853