When a second hand digital ass'y that had been mounted in other product is to be re-used.
As adjustment data for another product are already stored in the secondhand DIGITAL Assy, first delete those data then copy the backup data stored in the EEPROM on the SENSOR Assy.
Copying, using the Factory menu
- Plug in the AC cord, press the Power switch on the unit to set it to ON, then enter Standby mode.
- Turn on the power, using the remote control unit, then enter Panel Factory mode. Copy the backup data, as shown in the figure below:
CLICK ON PICTURE TO ZOOM
- Turn the power off.
Copying, using the RS-232C commands
- Turn on the unit, using the remote control unit or by issuing the PON command. Then issue the FAY command.
- Issue the UAJ command to delete data stored in the EEPROM on the DIGITAL Assy.
- Issue the BCP command to transfer the data stored in the EEPROM for backup.
- Turn the power off.