TROUBLESHOOTING
NO POWER
NO AUDIO
CLICK ON THE PICTURES TO ZOOM IN
NO VIDEOSERVICE MODE
- While pressing the Volume (-) button on the TV, press the Number Key (1)on the remote control unit. The service menu screen shown as below will be displayed.
- Press Menu UP/DN key to select the desired service menu.
- Press channel Up/Dn key to skip up or down 10 items.
- Use MenuRight/Left key to adjust the data.
- Press Menu key to Exit service mode.
Power failure 1: (Normal: High, Failure: Low). Detected voltage failure for analog circuit [Connected to IC801 pin 52]
Power failure 2: (Normal: Low, Failure: High). Detected voltage failure for audio AMPP IC. [Connected to IC801 pin 53]
Power failure 3: (Normal: High, Failure: Low). Detected voltage failure for digital circuit. [Connected to IC801 pin 54]
Temperature Failure : (Normal: Low, Failure: High) Detected temperature failure for Main Power Unit [Connected to IC801 pin 57]
LED Flashing
When IC801 detects the Power Failure the LED will flash to indicate a power failure has occurred. The type of failure detected as shown below will determine the number of flashes. If power failure is detected 3 times, the set will enter the standby mode, and cannot be switched ON. To reset the operating programs of the CPU, it is necessary to disconnect the AC cord for a short time. When finishing the repair or stopping the Power Failure, the history of past failures can be checked.TO SEE THE HISTORY
Enter service mode.
Select item number [355] POWER ERROR from the service adjustment data table.If simultaneous failures have been detected, the sum of each data is displayed. For example:
Power failures 1&2
01h + 10h = 11h (17)
After finishing service, reset the data of item No>355 with the < or > keys to ‘00h(0).