PANASONIC TH-37PX50U – TH-42PX50U – TH-50PX50U - DRIVER SETUP - QUICK ADJUSTMENTS AFTER BOARD EXCHANGE - Adjustment Volume Location - Test Points - Hotel Mode

$
0
0


PREPARATION 
  • Input an APL 100 % white signal.
  • Set the picture controls: -Picture mode: Normal.  White balance: Cool.  Aspect: 16:9.
ADJUSTMENTS
Adjust driver section voltages referring the panel data on the panel data label.
TH-37PX50U
TH-42PX50U
TH-50PX50U
PANEL LABEL INFORMATION
PRINTED CIRCUIT BOARD EXCHANGE
To remove P.C.B. wait 1 minute after power was off for discharge from electrolysis capacitors.
QUICK ADJUSTMENT AFTER BOARD EXCHANGE {Click on pictures to Magnify}
TH-37PX50U
TH-42PX50U
TH-50PX50U
ADJUSTMENT VOLUME LOCATION & TEST POINTS
TH-37PX50U
TEST POINTS

TH-42PX50U
TEST POINTS

TH-50PX50U
TEST POINTS

HOTEL MODE
Access command
  • Press MUTE button on remote control. Hold few seconds.
  • Press the CH ▲/▼ button and VOL ▲/▼  button to Set the data of EEPROM(ADDRESS 1584) to 01
  • Push the Power switch (button) off/on the set (the remote control) to turn the set off/on.
TO EXIT HOTEL MODE
  • First, set the data of EEPROM (ADDRESS 1584) to 00.
  • Push the Power switch (button) off/on the set (the remote control) to turn the set off/on.  Then, it is no longer hotel mode.
ACCESS COMMAND TO THE HOTEL MODE SETUP MENU
In order to display the Hotel mode setup menu, enter the following command (within 2 second).
[TV] : Vol.  + [REMOTE] : TV/VIDEO (3 times).