Quantcast
Channel: Electro help
Viewing all articles
Browse latest Browse all 2033

AKIRA MICROWAVE OVEN - MW700M17L - TROUBLESHOOTING - SCHEMATIC

$
0
0

WIRING
TROUBLESHOOTING
THERMAL PROTECTOR REMOVAL
1.  Unplug the power cord, remove the outer cabinet and discharge the capacitor.
2.  Disconnect the connectors from the thermal protector terminals.
3.  Remove the thermal protector mounting screw.
4.  Remove the thermal protector.
5.  Reverse procedure to replace.
MAGNETRON ASSEMBLY REMOVAL
1.  Unplug the power cord, remove the cabinet and discharge the capacitor.
2.  Remove the front and rear air guides and thermal protector from the magnetron.
3.  Remove the four-magnetron mounting screws from the side of oven cavity.
4.  Disconnect wire leads from magnetron and replace on new magnetron, wire for wire.
5.  Reverse the above procedure to reinstall new magnetron and reassemble.
NOTE: DO NOT LOSE SCREWS, THEY ARE M4 METRIC.
IMPORTANT: DO NOT OPERATE THE OVEN WITH THE MAGNETRON DISASSEMBLED FROM THE WAVE-GUIDE
Thermal Protector


Viewing all articles
Browse latest Browse all 2033

Trending Articles